| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200 | 
							- using System;
 
- using System.Collections.Generic;
 
- using System.IO;
 
- using System.Linq;
 
- using System.Reflection.Emit;
 
- using System.Text;
 
- using SqlSugar;
 
- using WCS.Data;
 
- using WCS.Data.Models;
 
- namespace WCS_Client.Frm
 
- {
 
-     public class Current
 
-     {
 
-         public static List<WCS_TASK> TaskSet = new List<WCS_TASK>();
 
-         /// <summary>
 
-         /// plc列表
 
-         /// </summary>
 
-         public static List<WCS_PLC> PlcSet = new List<WCS_PLC>();
 
-         public static void InitData(string wcssystem)
 
-         {
 
-             string result = TryCachHelper.TryExecute((db) =>
 
-              {
 
-                  PlcSet = db.Queryable<WCS_PLC>().Where(v => v.PLC_WCSSYSTEM == wcssystem).ToList();
 
-                  foreach (var plc in PlcSet)
 
-                  {
 
-                      plc.WCS_DBSet = db.Queryable<WCS_DBDEFINITION>().Where(v => v.DB_PLCNAME == plc.PLC_NAME).ToList();
 
-                      plc.WCS_ScannSet = db.Queryable<WCS_SCANN>().Where(v => v.SCANN_PLCNAME == plc.PLC_NAME).OrderBy(v => v.SCANN_SEQUENCE).ToList();
 
-                      plc.WCS_EquipmentInfoSet = db.Queryable<WCS_EQUIPMENTINFO>().Where(v => v.Equ_PlcName == plc.PLC_NAME).OrderBy(v => v.Equ_Sequence).ToList();
 
-                      foreach (var item in plc.WCS_EquipmentInfoSet)
 
-                      {
 
-                          var equDBInfoSet = GetConvDBInfo(plc, item);
 
-                          if (item.Equ_Type.ToLower().Trim() == EquipmentType.conveyor.ToString())
 
-                          {
 
-                              item.EquSignal = new ConvSignal(item.Equ_PlcName, equDBInfoSet);
 
-                          }
 
-                          else if (item.Equ_Type.ToLower().Trim() == EquipmentType.srm.ToString())
 
-                          {
 
-                              item.EquSignal = new SrmSignal(item.Equ_PlcName, equDBInfoSet);
 
-                          }
 
-                          else if (item.Equ_Type.ToLower().Trim() == EquipmentType.rgv.ToString())
 
-                          {
 
-                              item.EquSignal = new RGVSignal(item.Equ_PlcName, equDBInfoSet);
 
-                          }
 
-                      }
 
-                      plc.Init();
 
-                  }
 
-              });
 
-         }
 
-         public static void RefreshData(bool isRefreshTask = false)
 
-         {
 
-             TryCachHelper.TryExecute((db) =>
 
-             {
 
-                 if (isRefreshTask)
 
-                 {
 
-                     TaskSet = db.Queryable<WCS_TASK>().ToList();
 
-                 }
 
-                 foreach (var plc in PlcSet)
 
-                 {
 
-                     plc.WCS_DBSet = db.Queryable<WCS_DBDEFINITION>().Where(v => v.DB_PLCNAME == plc.PLC_NAME).ToList();
 
-                 }
 
-             });
 
-         }
 
-         private static List<ConvDbInfo> GetConvDBInfo(WCS_PLC plc, WCS_EQUIPMENTINFO item)
 
-         {
 
-             List<ConvDbInfo> equDBInfoSet = new List<ConvDbInfo>();
 
-             var dbSet = plc.WCS_DBSet.Where(v => v.DB_PLCNAME == item.Equ_PlcName).ToList();
 
-             foreach (var DB in dbSet)
 
-             {
 
-                 if (DB.DB_TYPE == (int)DB_TypeEnum.WCS可读可写DB)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_ReadWriteDB_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS可读可写DB;
 
-                     convdb.DBReadLength = item.Equ_ReadWriteDB_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_ReadWriteDB_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = temp_sequence * item.Equ_ReadWriteDB_Length; //plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_ReadWriteDB_Sequence) == false && Convert.ToInt32(v.Equ_ReadWriteDB_Sequence) < temp_sequence).Sum(v => v.Equ_ReadWriteDB_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-                 else if (DB.DB_TYPE == (int)DB_TypeEnum.WCS只读DB)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_ReadDB_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS只读DB;
 
-                     convdb.DBReadLength = item.Equ_ReadDB_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_ReadDB_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = temp_sequence * item.Equ_ReadDB_Length; //plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_ReadDB_Sequence) == false && Convert.ToInt32(v.Equ_ReadDB_Sequence) < temp_sequence).Sum(v => v.Equ_ReadDB_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-                 else if (DB.DB_TYPE == (int)DB_TypeEnum.WCS状态和故障DB)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_StatusDB_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS状态和故障DB;
 
-                     convdb.DBReadLength = item.Equ_StatusDB_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_StatusDB_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = temp_sequence * item.Equ_StatusDB_Length; //plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_StatusDB_Sequence) == false && Convert.ToInt32(v.Equ_StatusDB_Sequence) < temp_sequence).Sum(v => v.Equ_StatusDB_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-                 else if (DB.DB_TYPE == (int)DB_TypeEnum.WCS读取扫码DB)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_BarCodeDB_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS读取扫码DB;
 
-                     convdb.DBReadLength = item.Equ_BarCodeDB_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_BarCodeDB_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_BarCodeDB_Sequence) == false && Convert.ToInt32(v.Equ_BarCodeDB_Sequence) < temp_sequence).Sum(v => v.Equ_BarCodeDB_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     convdb.ScannSet = plc.WCS_ScannSet.Where(v => v.SCANN_STATIONNO == item.Equ_No).OrderBy(v => v.SCANN_SEQUENCE).ToList();
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-                 else if (DB.DB_TYPE == (int)DB_TypeEnum.WCS读写扩展DB1)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_ExtendOne_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS读写扩展DB1;
 
-                     convdb.DBReadLength = item.Equ_ExtendOne_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_ExtendOne_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_ExtendOne_Sequence) == false && Convert.ToInt32(v.Equ_ExtendOne_Sequence) < temp_sequence).Sum(v => v.Equ_ExtendOne_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     convdb.ScannSet = plc.WCS_ScannSet.Where(v => v.SCANN_STATIONNO == item.Equ_No).OrderBy(v => v.SCANN_SEQUENCE).ToList();
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-                 else if (DB.DB_TYPE == (int)DB_TypeEnum.WCS读写扩展DB2)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_ExtendTwo_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS读写扩展DB2;
 
-                     convdb.DBReadLength = item.Equ_ExtendTwo_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_ExtendTwo_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_ExtendTwo_Sequence) == false && Convert.ToInt32(v.Equ_ExtendTwo_Sequence) < temp_sequence).Sum(v => v.Equ_ExtendTwo_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     convdb.ScannSet = plc.WCS_ScannSet.Where(v => v.SCANN_STATIONNO == item.Equ_No).OrderBy(v => v.SCANN_SEQUENCE).ToList();
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-                 else if (DB.DB_TYPE == (int)DB_TypeEnum.WCS读写扩展DB3)
 
-                 {
 
-                     if (string.IsNullOrWhiteSpace(item.Equ_ExtendThree_Sequence)) continue;
 
-                     var convdb = new ConvDbInfo();
 
-                     convdb.DBName = DB.DB_NAME;
 
-                     convdb.DBType = DB_TypeEnum.WCS读写扩展DB3;
 
-                     convdb.DBReadLength = item.Equ_ExtendThree_Length;
 
-                     //convdb.DBReadIndox = item.Equ_ReadWriteDB_Sequence * item.Equ_ReadWriteDB_Length;
 
-                     int temp_sequence = Convert.ToInt32(item.Equ_ExtendThree_Sequence);
 
-                     if (temp_sequence != 0)
 
-                     {
 
-                         int Totallength = plc.WCS_EquipmentInfoSet.Where(v => string.IsNullOrWhiteSpace(v.Equ_ExtendThree_Sequence) == false && Convert.ToInt32(v.Equ_ExtendThree_Sequence) < temp_sequence).Sum(v => v.Equ_ExtendThree_Length);
 
-                         convdb.DBReadIndox = Totallength;
 
-                     }
 
-                     convdb.ScannSet = plc.WCS_ScannSet.Where(v => v.SCANN_STATIONNO == item.Equ_No).OrderBy(v => v.SCANN_SEQUENCE).ToList();
 
-                     equDBInfoSet.Add(convdb);
 
-                 }
 
-             }
 
-             return equDBInfoSet;
 
-         }
 
-     }
 
- }
 
 
  |