| 12345678910111213141516171819202122232425262728293031323334 | 
							- using System;
 
- using System.Collections.Generic;
 
- using PLC.Siemens.Protocol.Common;
 
- using PLC.Siemens.Protocol.ReadData;
 
- using PLC.Siemens.O;
 
- namespace PLC.Siemens.ProtocolHandle
 
- {
 
-     public class ReadMultiHandle:IPacketHandle
 
-     {
 
-         public ushort PduLength { get; set; }
 
-         public List<DataItem> DataItem { get; set; }
 
-         public ResultCode ResultCode { get; private set; }
 
-         public void Handle(IIsoSender sender)
 
-         {
 
-             ReadRequest read = new ReadRequest();
 
-             read.ListItems = DataItem;
 
-             ReadResponse res = sender.IsoSend<ReadRequest, ReadResponse>(read);
 
-             ResultCode = res.Header.Error;
 
-             if (ResultCode == ResultCode.OK)
 
-             {
 
-                 for (int i = 0; i < res.DataItems.Count; i++)
 
-                 {
 
-                     var reqItem = DataItem[i];
 
-                     var resItem = res.DataItems[i];
 
-                     reqItem.Err = (ResultCode)resItem.ReturnCode;
 
-                     reqItem.Data = resItem.Data;
 
-                     if (reqItem.Err == ResultCode.OKFF)
 
-                         reqItem.Err = ResultCode.OK;
 
-                 }
 
-             }
 
-         }
 
-     }
 
- }
 
 
  |