| 123456789101112131415161718192021222324252627282930313233343536 | 
							- using System;
 
- using System.Collections.Generic;
 
- using PLC.Siemens.Protocol.Common;
 
- using PLC.Siemens.Protocol.ReadData;
 
- using PLC.Siemens.Protocol.WriteData;
 
- using PLC.Siemens.O;
 
- namespace PLC.Siemens.ProtocolHandle
 
- {
 
-     public class WriteMultiHandle:IPacketHandle
 
-     {
 
-         public ushort PduLength { get; set; }
 
-         public List<DataItem> DataItem { get; set; }
 
-         public ResultCode ResultCode { get; private set; }
 
-         public void Handle(IIsoSender sender)
 
-         {
 
-             WriteRequest write = new WriteRequest();
 
-             write.DataItems = DataItem;
 
-             var res = sender.IsoSend<WriteRequest, WriteResponse>(write);
 
-             ResultCode = res.Header.Error;
 
-             if (ResultCode == ResultCode.OK)
 
-             {
 
-                 for (int i = 0; i < res.Data.Length; i++)
 
-                 {
 
-                     var reqItem = DataItem[i];
 
-                     var resItem = res.Data[i];
 
-                     reqItem.Err = (ResultCode)resItem.ReturnCode;
 
-                     if (reqItem.Err == ResultCode.OKFF)
 
-                         reqItem.Err = ResultCode.OK;
 
-                 }
 
-             }
 
-         }
 
-     }
 
- }
 
 
  |