| 1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950 | 
							- using Core.Communication.Transport;
 
- using PLC.Siemens.Protocol.Header;
 
- using PLC.Siemens.O;
 
- namespace PLC.Siemens.Protocol.DateTime
 
- {
 
-     public class GetDateTimeResponse :IBuildResponse
 
-     {
 
-         public HeaderPacket Header { get; set; }
 
-         public ParamsResponse Params { get; set; }
 
-         public DateTimeData Data { get; set; }
 
-         public GetDateTimeResponse()
 
-         {
 
-             Header = new HeaderPacket();
 
-             Params = new ParamsResponse();
 
-             Data = new DateTimeData();
 
-         }
 
-         public void Build(ByteBuffer buffer)
 
-         {
 
-             Header.Build(buffer);
 
-             Params.Build(buffer);
 
-             Data.Build(buffer);
 
-         }
 
-         private int BcDtoByte(byte B)
 
-         {
 
-             return ((B >> 4) * 10) + (B & 0x0F);
 
-         }
 
-         public System.DateTime GetDateTime()
 
-         {
 
-             var year = BcDtoByte(Data.Time[0]);
 
-             if (year < 90)
 
-                 year = year + 2000;
 
-             var mon = BcDtoByte(Data.Time[1]);
 
-             var day = BcDtoByte(Data.Time[2]);
 
-             var hour = BcDtoByte(Data.Time[3]);
 
-             var min = BcDtoByte(Data.Time[4]);
 
-             var sec = BcDtoByte(Data.Time[5]);
 
-             var wday = (Data.Time[7] & 0x0F);
 
-             System.DateTime dt = new System.DateTime(year, mon, day, hour, min, sec, wday);
 
-             return dt;
 
-         }
 
-     }
 
- }
 
 
  |