							- using Core.Communication.Transport;
 
- using Core.Util.Extension;
 
- using PLC.Siemens.Protocol.Common;
 
- namespace PLC.Siemens.Protocol.Control
 
- {
 
-     public class PlcHotStartParamsRequest
 
-     {
 
-         public byte Fun;     // start 0x28
 
-         public byte[] Uk7; // unknown 7
 
-         public ushort Len1;   // Length part 1 : 0x0002
 
-         //public ushort SFun;    // 'C ' 0x4320
 
-         public byte Len2;   // Length part 2 : 0x09
 
-         public char[] Cmd;  // ascii 'P_PROGRAM'
 
-         public ushort PacketLength   = 0x14;
 
-         public void Build()
 
-         {
 
-             Fun = (byte)PduFuncType.PduStart;
 
-             Uk7 = new byte[] { 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xFD };
 
-             Len1 = 0x0000;
 
-             //SFun = 0x00;
 
-             Len2 = 0x09;
 
-             Cmd = new[] { 'P', '_', 'P', 'R', 'O', 'G', 'R', 'A', 'M' };
 
-         }
 
-         public void GetByteBuffer(ByteBuffer buffer)
 
-         {
 
-             buffer.Push(Fun);
 
-             buffer.Push(Uk7);
 
-             buffer.Push(Len1);
 
-             //buffer.Push(SFun);
 
-             buffer.Push(Len2);
 
-             Cmd.ForEach(t => buffer.Push((byte)t));
 
-         }
 
-     }
 
- }
 
 
  |