| 12345678910111213141516171819202122232425262728293031323334353637 | 
							- using PlcSiemens.O;
 
- namespace PlcSiemens.Protocol.Iso
 
- {
 
-     public class CoptParams
 
-     {
 
-         public byte PduSizeCode { get; set; }
 
-         public byte PduSizeLen { get; set; }
 
-         public byte PduSizeVal { get; set; }
 
-         public byte[] Tsap { get; set; }
 
-         public int TsapLenth { get; set; }
 
-         public CoptParams()
 
-         {
 
-             Tsap = new byte[245]; // We don't know in advance these fields....
 
-         }
 
-         public void GetByteBuffer(ByteBuffer buffer)
 
-         {
 
-             buffer.Push(PduSizeCode);
 
-             buffer.Push(PduSizeLen);
 
-             buffer.Push(PduSizeVal);
 
-             buffer.Push(Tsap, 0, TsapLenth);
 
-         }
 
-         public void InitByBuffer(ByteBuffer buffer)
 
-         {
 
-             PduSizeCode = buffer.PopByte();
 
-             PduSizeLen = buffer.PopByte();
 
-             PduSizeVal = buffer.PopByte();
 
-             TsapLenth = buffer.WriteIndex - buffer.ReadIndex;
 
-             Tsap = buffer.PopBytes(TsapLenth);
 
-         }
 
-     }
 
-     // COTP Header for DATA EXCHANGE
 
- }
 
 
  |